ZL-1 Input Refrigerator is specially designed and made according to
the specific climatic conditions of China and the specific needs of
the laboratory. When the room temperature is higher than the
experimental temperature and the test bath needs to be cooled, it
can be conveniently placed in the experimental container to
directly cool the liquid in the container.
Portable refrigeratior
I. Main technical features
The instrument is compact, portable, fast refrigeration, good
effect, easy to use.
This instrument can be used with the company's oil product
anti-foam tester, oil product density tester, oil product kinematic
viscosity tester and other kinds of need to cool down, constant
temperature test bath matching;
At the same time, it can also be used as a refrigeration source for
all kinds of test bath cooling and constant temperature work. It is
a widely used general equipment for laboratory cooling and constant
temperature.

II. Main technical parameters and indicators
1. Power supply: AC220V±10%, 50Hz;
2. Total power: 200W;
3. Refrigeration compressor: fully enclosed compressor;
4, the use of working medium: environmentally friendly R134A;
5, ambient temperature: (5 ~ 35)℃;
6, relative humidity: ≤85%;
7, instrument material: all 304 stainless steel production
8, Dimensions: 350㎜×280㎜×300㎜ (length × width × height);
9, the use of the environment: the surrounding environment without
strong vibration and magnetic field, no dust and corrosive gas.
Refrigeration head size: φ 32*200mm

| Power supply | AC220V±10%, 50Hz; |
| Total power | 200W |
| Refrigeration compressor | fully enclosed compressor |
| Ambient temperature | (5 ~ 35)℃; |
| relative humidity | ≤85%; |
| instrument material | all 304 stainless steel production |
| Dimensions | 350×280×300mm(length × width × height); |
| Refrigeration head size: | φ 32*200mm |
| the use of the environment | the surrounding environment without strong vibration and magnetic
field, no dust and corrosive gas. |
Simple operation
1. The instrument should be kept dry and clean.
2. After the instrument is turned off, it should stay for at least
20 minutes before starting up, otherwise it will reduce the service
life of the compressor, or even damage the compressor.
3. After the instrument is used, first turn off the power switch,
unplug the power plug, and carefully take out the probe of the
refrigerator from the constant temperature bath.

ZL-1 Input Refrigerator is specially designed and made according to
the specific climatic conditions of China and the specific needs of
the laboratory. When the room temperature is higher than the
experimental temperature and the test bath needs to be cooled, it
can be conveniently placed in the experimental container to
directly cool the liquid in the container.
Portable refrigeratior
I. Main technical features
The instrument is compact, portable, fast refrigeration, good
effect, easy to use.
This instrument can be used with the company's oil product
anti-foam tester, oil product density tester, oil product kinematic
viscosity tester and other kinds of need to cool down, constant
temperature test bath matching;
At the same time, it can also be used as a refrigeration source for
all kinds of test bath cooling and constant temperature work. It is
a widely used general equipment for laboratory cooling and constant
temperature.
II. Main technical parameters and indicators
1. Power supply: AC220V±10%, 50Hz;
2. Total power: 200W;
3. Refrigeration compressor: fully enclosed compressor;
4, the use of working medium: environmentally friendly R134A;
5, ambient temperature: (5 ~ 35)℃;
6, relative humidity: ≤85%;
7, instrument material: all 304 stainless steel production
8, Dimensions: 350㎜×280㎜×300㎜ (length × width × height);
9, the use of the environment: the surrounding environment without
strong vibration and magnetic field, no dust and corrosive gas.
Refrigeration head size: φ 32*200mm
| Power supply | AC220V±10%, 50Hz; |
| Total power | 200W |
| Refrigeration compressor | fully enclosed compressor |
| Ambient temperature | (5 ~ 35)℃; |
| relative humidity | ≤85%; |
| instrument material | all 304 stainless steel production |
| Dimensions | 350×280×300mm(length × width × height); |
| Refrigeration head size: | φ 32*200mm |
| the use of the environment | the surrounding environment without strong vibration and magnetic
field, no dust and corrosive gas. |
Simple operation
1. The instrument should be kept dry and clean.
2. After the instrument is turned off, it should stay for at least
20 minutes before starting up, otherwise it will reduce the service
life of the compressor, or even damage the compressor.
3. After the instrument is used, first turn off the power switch,
unplug the power plug, and carefully take out the probe of the
refrigerator from the constant temperature bath.